Pulse-width modulation (PWM)
allows power reduction by switching the signal to on and off and breaking signals
into discrete parts. A common use of PWM is for adjusting the speed of the motor or
adjusting the brightness of a light source. In PWM, the duty cycle is the amount of
time the switch is on to the entire period. Figure 2 shows the PWM graph
changing its average voltage, which is dependent on the duty cycle.
When including the PWM
frequency, which is the amount of duty cycle per second, the output is the average voltage which takes the total area of the “on” cycle by the entire
period. Ignoring qualitative PWM frequency, the average voltage is the provided
voltage multiplied by the duty cycle percentage.
During a DC motor connection
with the PWM, the circuit sees Ohmic resistance and inductance. In all series
RL circuit, the time constant is present, which is inductance value over resistance
value. T is the time it takes for the voltage to reach 1/e of the final value.
VR = V (1–1/e)
As the back EMF caused by the inductor slows down the
inductance, the current of the motor is prevented from instant changes, which
is a characteristic of the voltage. With this, figure 3 shows a graph of both
voltage and current of a DC motor when the PWM cycle is at 50%. Green line is
the voltage and purple line is the current.